Dec 21, 2020
Beth Parker; Jonathan Munn; Jonathan Kennel; Carlos Maldaner; Emmanuelle Arnaud, 2020, "Replication Data for: Variable flow directions measured at discrete depths in a bedrock aquifer using multi-borehole Active Distributed Temperature Sensing", https://doi.org/10.5683/SP2/HC5V47, Borealis, V1, UNF:6:N647dO2LbFDrla6Nwf5Azg== [fileUNF]
Data collected at the Fractured Rock Observatory on the University of Guelph Campus in Guelph, Ontario, Canada. Temperature data is from boreholes GDC-06, GDC-07, GDC-08, and GDC-09 sealed with a flexible and impermeable liner during two Active-Distributed Temperature Sensing (A-...
Jan 29, 2020
Parker, Beth; Munn, Jonathan; Maldaner, Carlos; Coleman, Thomas, 2020, "Replication Data for: Measuring groundwater flow changes in a fractured bedrock aquifer under ambient and open hole conditions using Active Distributed Temperature Sensing", https://doi.org/10.5683/SP2/GLFIZE, Borealis, V1, UNF:6:ziqd+Tv09pLNe0BtnPPFrg== [fileUNF]
Temperature data collected in borehole GDC-07, sealed with a flexible and impermeable liner during three Active-Distributed Temperature Sensing (A-DTS) tests. The first test (Sealed) was collected with all boreholes on the site sealed with liners to restore natural gradient condi...
Jan 29, 2020
Beth Parker; Carlos Maldaner; Jonathan Munn, 2018, "Replication Data for: Groundwater flow quantification in fractured rock boreholes using active distributed temperature sensing under natural gradient conditions", https://doi.org/10.5683/SP2/FZJAWP, Borealis, V2, UNF:6:sNEhAUvkCaRELkgaie1FYw== [fileUNF]
Temperature data collected in borehole GDC-05 sealed with a flexible and impermeable liner during an active distributed temperature sensing test. The test consisted of measuring the background temperature for 30 minutes before the composite fiber optic cable is heated at a consta...